Louvres, dampers, vav & cav systems
4S1 |
- External Louvres: FŽ, AFŽV, AFŽM |
|
- Multi-Leaf Dampers: RŽ, ARŽ |
|
- Pressure Relief Dampers PŽ |
|
- Combined Louvres and Dampers: FŽ+PŽ, FŽ+RŽ |
|
- Sand-Trap Louvres ŽP |
Fixed and overpressure louvres are used for covering different gaps in air-conditioning and ventilation systems. They are made of galvanised sheet steel and aluminium profiles. Multi-leaf dampers are used for air volume and pressure control. Sand-trap louvres are used for separation of sand from air stream. Combined louvres are combinations of a fixed louvres and pressure relief dampers or fixed louvres and multi-leaf dampers. They are used in zones with big wind velocity, whan it is neccessary to install fixed louvres, in front of multi-leaf dampers or pressure relief dampers.
4S1_Louvres.pdf
4S2 |
- Reinforced Multi-Leaf Dampers: RŽO-12, RŽO-18, RŽO-20 |
Reinforced multi-leaf dampers are intended for application in hard working enviroment with regard to temperature. Casing and blades are made of thick, additionally reinforced, galvanized sheet steel. Stainless steel version is also available at request.
 |
| RZO |
|
|
|
4S2_Louvres.pdf
4S3 |
- Air Volume Control Dampers |
|
- Round RZ-C |
|
- Rectangular RZ-P |
Air volume control dampers serves for manual regulation/control of airflow in ventilation. It is made of galvanised sheet steel. Smaller sizes have plastic control mechanism and bigger sizes have metal control mechanism.
 |
| RZ-C |
|
 |
| RZ-P |
|
|
4S3_Louvres.pdf
4S4 |
- Aound Air-tight Damper ZTZ-C |
Air-tight dampers are used to shut off volume flows in ducts of ventilation and air-conditioning systems. It is tested to DIN 1946 (part 4). Damper can be operated manually or actuated by an electric motor. It consists of casing, damper blade and attached mechanism. The majority of damper parts are made of galvanised sheet steel, while the bearings are made of brass.
 |
| ZTZ-C |
|
|
|
4S4_Louvres.pdf
4S5 |
- Round Backdraught Dampers |
Round backdraught dampers are used for independent closing of ventilation ducts in ventilation systems after the fan is turned off. It also prevents unwanted air flow (warm air flowing out or cold air flowing in). Casings are made of galvanised sheet steel and blades are made of thin aluminium sheet. They are designed, so that blades and the spring system prevent a considerable drop in pressure.
 |
| ZPC |
|
|
|
4S5_Louvres.pdf
4S6 |
- Round Variable Air Volume Control Damper RVP-C |
4S7 |
- Rectangular Air Volume Control Damper RVP-P |
Rectangular Air Volume Control Damper RVP-P
Air volume control dampers enable regulation of supply or exhaust air volume in ventilation systems. Depending on project requirements it can be controlled over temperature, quality, occupancy or some other sensor. Data about measured differential pressure is transfered to the motor mechanism where it is beeing compared with reference signal. Depending on the difference, mechanism is opening or closing the damper and assures the optimal air volume in the room.
 |
| RVP-C |
|
 |
| RVP-P |
|
|
4S6_Louvres.pdf
4S7_Louvres.pdf
4S8 |
- Round Constant Air Volume Control Damper RKP-C |
4S9 |
- Rectangular Constant Air Volume Control Damper RKP-P |
Control dampers are installed in supply and exhaust air ducts and ventilation systems with purpose of keeping constant air volume regardless of pressure changes. They do not use any additional power source for functioning. Constant air volume is enabled through a balance between the aerodynamic force and force of closing mechanism spring unaffected by air pressure changes inside the system.
 |
| RKP-C |
|
 |
| RKP-P |
|
|
4S8_Louvres.pdf
4S9_Louvres.pdf
|